Air Source Heat Pump Installation

VAYU designed and installed a full air source heat pump system at 11 Kings View in Southowram, Halifax.

The project included a Viessmann Vitocal 150-A air source heat pump, upgraded radiators where required, twin hot water cylinders in the loft, smart customer controls and real-world performance monitoring.

This was not a simple boiler swap. The system was designed around the property, the heat loss of each room, the hot water demand and how the customer would use the heating day to day


Project Details

Location: Southowram, Halifax
System: Viessmann Vitocal 150-A
Heat pump size: 8kW
Heat loss: Approx. 6kW
Hot water: 2 × 150L slimline cylinders
Design flow temperature: 45°C
Monitoring: OpenEnergyMonitor
Project value: £18,500
BUS grant: £7,500
Cost to customer: £11,000


The Brief

The customer wanted a modern, low-carbon heating and hot water system that could replace the existing setup and work efficiently in real life.

The property needed a proper design process before installation. We had to consider the size of each room, the existing radiators, the pipework, hot water storage, loft space, cylinder weight, controls and future system performance.

Our aim was to design a system that would keep the home comfortable, provide reliable hot water and run as efficiently as possible.


Why the Survey Matters

A good heat pump installation starts with a proper survey.

Before choosing the final system, we measured the property, checked the rooms, looked at the radiators, reviewed the pipework and worked out how much heat the home actually needed.

This matters because a heat pump should not be guessed.

If the survey or design is wrong, the system may need to run at higher temperatures, cost more to operate, or struggle to keep the home comfortable.

At VAYU, we spend time on the design before installation so the system is built around the property, not just the old boiler size.


Room-by-Room Heat Loss

For 11 Kings View, we calculated how much heat each room needed.

Every room loses heat differently depending on its size, windows, walls, insulation and position in the property.

By working this out properly, we could check whether the existing radiators were suitable and identify where upgrades were needed.

This helped us design the system to run at lower temperatures, which is important for heat pump efficiency.


System Design

Once the heat loss was known, we designed the system around the property.

This included:

  • Heat pump sizing
  • Radiator checks and upgrades
  • Pipework design
  • Hot water storage
  • Flow temperature
  • Cylinder location
  • Controls
  • Monitoring

A heat pump works best when the full heating system is designed to work together.

It is not just about fitting an outdoor unit. The radiators, pipework, hot water cylinders, controls and settings all matter.


Weather Compensation

The system was set up to adjust automatically depending on the temperature outside.

On milder days, the heat pump can run at lower temperatures. On colder days, it increases gradually to keep the home comfortable.

This helps the system run smoothly, instead of constantly switching on and off.

When set up properly, this can improve comfort and help the heat pump run more efficiently.


Loft Cylinder Design

The hot water cylinders were installed in the loft due to space restrictions inside the property.

Because two full cylinders carry a lot of weight, we did not simply sit them on the existing loft floor.

A support arrangement was designed and fixed back to a suitable load-bearing wall, giving the cylinders a safe and practical location.

This is a good example of why heat pump installations need to be designed around the actual property. Every home is different, and the details matter.


Customer Controls

The customer can control the system through the Viessmann ViCare app.

This allows them to:

  • See the current hot water temperature
  • Boost hot water when needed
  • Change hot water schedules
  • Change heating schedules
  • Adjust heating modes
  • Use comfort, normal and reduced settings

The aim is to give the customer simple control over heating and hot water, without making the system complicated to use.


Real-World Monitoring

The system is connected to OpenEnergyMonitor, allowing performance to be checked after installation.

This lets us see how the heat pump is actually running in real life, including electricity use, flow temperatures, hot water cycles and heating performance.

For VAYU, monitoring is important because good design should not stop once the installation is finished.

It allows us to check performance, make improvements where needed and learn from real data.


The Result

11 Kings View now has a properly designed low-carbon heating and hot water system.

The installation includes a Viessmann air source heat pump, upgraded emitters, twin hot water cylinders, app-based controls and live performance monitoring.

The system was designed around the home, not guessed from the old boiler.

At VAYU, we believe the survey, design and setup are just as important as the installation itself.

Read More:

Hot Water Design

Infiltration Heat Loss

Time of Use Tariffs